News

Machine room

All 6 isidaten articles on Machine room, newest first.

Series overview with schedule

Cabling documentation is only right until the next emergency patch
05.11.2026

Cabling documentation is only right until the next emergency patch

Machine room, part 6: what is plugged into the distribution frame is not what the plan says. The previous Kompendium had clear deadlines for this: the working version on the same day, the master documentation after four weeks, a check of documentation accuracy after four years at the latest. Why cabling documentation needs an inventory and what the network devices themselves say about it.

Read more
The emergency power chain is only as good as its last test run
29.10.2026

The emergency power chain is only as good as its last test run

Machine room, part 5: UPS, standby generator, switchover, cooling. Every link can be maintained and ticked off on its own, and the server room still goes down in a real power cut. What Grundschutz++ and the previous Kompendium say about load tests and function tests, and why the chain has to be tested as a whole.

Read more
A forgotten server still draws power
22.10.2026

A forgotten server still draws power

Machine room, part 4: almost every server room has a device that nobody needs any more and nobody wants to switch off. It draws power, has to be cooled and occupies rack units. What the Energy Efficiency Act requires, why switching off fails on ownership, and how to find ghost servers without hitting a production server.

Read more
A/B is only redundant when each side carries the load alone
15.10.2026

A/B is only redundant when each side carries the load alone

Machine room, part 3: two power rails, two strips per rack, every server with two power supplies. On the plan, that is redundant. Whether it really is depends on three things: the load on each side, where A and B join, and the devices whose second power supply is plugged into the same strip. What IT-Grundschutz says about it and how to check.

Read more
A data centre for the BSI, not for the Energy Efficiency Act
08.10.2026

A data centre for the BSI, not for the Energy Efficiency Act

Machine room, part 2: three racks in the basement, forty kilowatts, "we don't have a data centre". For the German Energy Efficiency Act that is true, because it counts kilowatts and starts at 300. IT-Grundschutz counts something else: importance for the organisation's tasks. On that basis, the only central server room is generally to be treated like a data centre. Two definitions, two different answers to the same question.

Read more
A PUE from the data sheet is not a measurement
01.10.2026

A PUE from the data sheet is not a measurement

Machine room, part 1: from 1 July 2027 a statutory PUE limit applies to existing data centres in Germany, as an annual average. Many have a PUE, but often from the data sheet, from rated power or from a cool day in February. What the Energy Efficiency Act means by the metric, where it can be flattered, and why the amendment does not change that.

Read more