In Advent, boxes stand in the corridor, the Christmas tree in front of the glass door, and the emergency exit is locked because there is storage behind it. German workplace regulations require escape routes to be kept clear at all times and doors to be easy to open from the inside. Why this so often slips in daily work, and why access control and escape routes can get in each other's way.

The end of November. The delivery for the Christmas party sits in boxes in the corridor, "just until Friday". The Christmas tree goes up in front of the glass door to the stairwell, because there is room there. And the door at the end of the corridor, the one with the green sign, is locked because the archive has been behind it since the move.

None of these decisions is meant carelessly. Together they make a corridor through which nobody gets out quickly in a fire.

What the German Workplaces Ordinance requires

Section 4(4) of the Workplaces Ordinance (ArbStättV) is brief and clear. The employer must ensure that traffic routes, escape routes and emergency exits are kept clear at all times so that they can be used at any time. The employer must draw up an escape and rescue plan where the location, size and type of use of the workplace require it, display it in suitable places, and practise according to this plan at appropriate intervals.

Annex 2.3 adds requirements for doors. Doors along escape routes and emergency exit doors must be easy to open from the inside without special aids at any time while employees are in the workplace, and they must be permanently marked. Emergency exit doors must open outwards.

The details, with widths, route lengths, signage and the requirements for the plan, are set out in the technical rule ASR A2.3 (March 2022 edition, last amended 2024). Under section 3a(1) ArbStättV, anyone who complies with the published rules is presumed to meet the requirements of the ordinance.

Where it slips in daily work

  • "Just for a moment" becomes permanent. Boxes, mobile pedestals, a retired printer. Each item looks harmless, and nobody feels responsible for clearing it.
  • Access control versus escape route. From a security point of view a door should be closed; from an escape point of view it must open from the inside at any time. Locking an emergency exit because an archive, server room or storage area lies behind it solves one problem and creates the other. Solutions that meet both exist, but they have to be chosen deliberately.
  • The plan shows the old building. After a refurbishment, departments moving or a new fire door, the old plan often still hangs in the corridor.
  • Drills never happen. The ordinance requires drills based on the plan. Without them, neither the blocked route nor the sticking door is noticed.

What helps

Escape routes belong in every inspection walk, not just the annual one. A short walk with the current plan in hand, opening door after door from the inside, shows more than any checklist at a desk. And every drill should get a record with evacuation time and findings, followed by a measure if something was blocked.

In isidaten's occupational health and safety module, evacuation drills are recorded with duration and findings and linked to a measure. Defects from inspection walks, such as a blocked escape route, get a severity and a measure as well.

The test question

When did someone last walk the escape route shown on your plan, and get out through every door from the inside?

Product-related assessment, not legal advice.

Sources

German Workplaces Ordinance (ArbStättV), section 3a(1), section 4(4) and Annex no. 2.3, retrieved 15 November 2026.

BAuA, ASR A2.3 Escape routes and emergency exits, March 2022 edition, last amended GMBl 2024.

Questions about this update?

Talk to us – we are happy to show you this feature in a demo.